Eccomi
2009-02-06 21:22:42 UTC
Hello all:
I'm trying to power a piece of hardware and control certain inputs
using the NI 9263 device and the DAQ Assistant VI. I have previous
experience with data acquisition in Labview, but for outputs I am
admittedly a little stumped.
I found the following VI helpful for my setup:
http://digital.ni.com/public.nsf/allkb/44F1067EA1893DF586256F4D001A1E14
Modifying this VI was useful, but now I'd like to continuously switch
one input at a particular rate. How do I wire the data in to reflect
the (essentially) square-wave output I'd like to see? How do I change
the time-base for the analog output device?
I'm using all four analog outputs on the DAQ device, and the current
configuration I built has 4 bundles of 2 data values (max and min for
each output port, i assume) going into the data in connection on the
DAQ assistant. How do I change the dt attribute through this?
At one point, I had LabVIEW break the DAQ assistant VI down into its
omponents, of which I am using the setup vi containing the max and min
output values for each channel as well as some timing info. However,
altering this timing info does not seem to affect the output on the
device, so I am of the belief that I need to model everything using
the data in port on the DAQ assistant. Any help regarding timing
control on an analog output device usin LabVIEW would be immensely
helpful, thank you,
Daniel
I'm trying to power a piece of hardware and control certain inputs
using the NI 9263 device and the DAQ Assistant VI. I have previous
experience with data acquisition in Labview, but for outputs I am
admittedly a little stumped.
I found the following VI helpful for my setup:
http://digital.ni.com/public.nsf/allkb/44F1067EA1893DF586256F4D001A1E14
Modifying this VI was useful, but now I'd like to continuously switch
one input at a particular rate. How do I wire the data in to reflect
the (essentially) square-wave output I'd like to see? How do I change
the time-base for the analog output device?
I'm using all four analog outputs on the DAQ device, and the current
configuration I built has 4 bundles of 2 data values (max and min for
each output port, i assume) going into the data in connection on the
DAQ assistant. How do I change the dt attribute through this?
At one point, I had LabVIEW break the DAQ assistant VI down into its
omponents, of which I am using the setup vi containing the max and min
output values for each channel as well as some timing info. However,
altering this timing info does not seem to affect the output on the
device, so I am of the belief that I need to model everything using
the data in port on the DAQ assistant. Any help regarding timing
control on an analog output device usin LabVIEW would be immensely
helpful, thank you,
Daniel